热门
Holmak: Heat exchanger made of PET
"China Water efficiency label management" implem…
MOSTRA CONVEGNO EXPOCOMFORT (MCE) ASIA TO DEBUT…
Build Eco Xpo (BEX) Asia and Mostra Convegno Exp…
Global air conditioning systems market is expect…
CRAA published nameplate code of multi split air…
2019 China AC market marked by slide domestic sa…
Tube Heat Exchanger by Holmak: energy-efficient and ultra-compact
Staphorst, November 27, 2015 – The new plastic heat exchanger TSC 18 for decentral home ventilation is a true space saver and also highly energy-efficient due to its sophisticated design. With a diameter of just 180 mm, the small device by the dutch manufacturer Holmak reaches highly energy efficiencies, that otherwise can be achieved only by big central plate heat exchangers. Depending on the volumetric flow rate, more than 80 % of the exhaust air energy can be recovered. This enables the classification in energy class A+ in force on 2016 European standard EN 13141 (2015), which specifies the testing requirements for home ventilation systems. The so-called "eco-labels" are energy efficiency categories, ranging from top values such as A+ to minimum values as G.
Increasing importance of home ventilation with heat recovery
In highly insulated building shells less heat leaks, but in return no more fresh air seeps into the interior of a house. Poorly ventilated spaces can cause headache, allergies and even asthma. Dampness and mould can give rise to dilapidations. By extensive airing with open windows a lot of valuable heating and cooling energy gets lost. The only energy-conscious alternative to open windows is using a home ventilation system with heat recovery.
Counterflow principle saves heating costs
Holmak relies on the counterflow principle. When separate supply and return air flows pass each other in opposite directions, the warm air in one duct can heat up the cold air in the other duct by means of thin, highly conductive plastic tubes. This of course also works in reverse in summer, for cooling down warm air. TSC 18 achieves thermal efficiencies of more than 80 %. This counterflow heat exchanger keeps energy loss to a minimum.
Decentral home ventilation systems are of particular interest for the renovation market. For the new tube heat exchanger only a whole with a diameter of 180 mm in the exterior wall is necessary, where the compact heat exchanger will be installed together with the complete ventilation system. As an option, the TSC 18 can be ordered with a bypass function. This function is of special interest, if the colder external air should be used for the warmer interior air.
Captions:
Image 1: Small but excellent – ultra-compact tube heat exchanger TSC 18 from Holmak is highly compact and energy-efficient
Image 2: Holmak relies on the counterflow principle

Image 1

Image 2
Background Holmak HeatX
Holmak HeatX is an expert in the subject of air to air heat exchangers. At its headquarters in Staphorst, the Netherlands, the company develops and produces technologies and products that are based on the counterflow principle which is particularly efficient. Due to the specialisation and the use of state-of-the-art machines, Holmak achieved over the past few years a level of quality that is appreciated by international customers.
Holmak was established in 2007 and has production facilities in the Netherlands and Macedonia. The company is part of the CENTROTEC Group. The CENTROTEC Group has about 3,000 employees and has representatives in more than 50 countries all over the world.
Contact:
Mark Lammers, Managing Director
Email: marklammers@holmak.eu
Phone: +31 522 469900
Holmak HeatX
Wethouder Wassebaliestraat 8
7951 SN Staphorst
The Netherlands
www.holmak.eu



