高层住宅空调室外机位设置探究
Research on air conditioner outdoor unit position setting in high-rise residences
摘要:
介绍了现行规范对空调室外机位散热条件的规定,并对其在高层住宅设计中的适用性进行了分析。以某高层住宅项目凹槽内空调室外机位为研究对象,运用数值模拟软件对不同型号空调室外机在凹槽深度1.0~4.0 m条件下的机组运行工况进行了模拟。以机组平均进风温度为判定标准,得出满足空调室外机正常运行需求的室外机位条件,并将结论归纳为图表形式供设计师参考。
Abstract:
This paper presents the current codes’ provisions on heat dissipation conditions of air conditioner outdoor unit position, and analyses their adaptability in the high-rise residence design. Taking the air conditioner outdoor unit position in the groove of a high-rise residence as the research project, the unit operation conditions of air conditioner outdoor units with different types under the groove depth of 1.0 to 4.0 m are simulated by using numerical simulation software. Taking the average inlet air temperature of the unit as the judgment standard, the outdoor unit positions that meet the normal operation requirement of the air conditioner outdoor unit are obtained, and the conclusion is summarized into a chart form for the designer’s reference.
Keywords:high-rise residence; air conditioner; outdoor unit; groove; numerical simulation; inlet air temperature