建筑用相变材料热性能测试与评价综述
Review of thermal performance testing and evaluation for phase change materials applied to buildings
摘要:
综述了目前建筑用相变材料的热性能测试方法。在传统热分析法基础上归纳整理了相变储能构件的热物性测试装置及其测试原理,即对国内外相变试验台进行了概述,并结合相关标准对不同热性能测试方法进行了分析比较。基于热物性测试方法,结合实际环境下的实测研究,综述了国内外现有衡量相变材料在建筑物中应用效果的评价指标。
Abstract:
Reviews the thermal performance testing methods of phase change materials for buildings. Based on the conventional thermal analysis method, summarizes the thermal performance testing devices and their testing principles of phase change energy storage components. Presents the phase change testing benches at home and abroad, and compares different thermal performance testing methods combined with relevant standards. Based on different testing methods, combined with the measurement in actual environment, reviews the existing domestic and international evaluation indexes for measuring the effect of phase change materials applied to buildings.
Keywords:phase change material, thermal performance, hot box, guarded hot plate, testing standard, evaluation index