亚太地区空调器能效标准分析
Analysis of air conditioner energy efficiency standards in Asia-Pacific region
摘要:
对亚太地区主要国家的空调器能效标准进行了分析研究,发现亚太地区主要国家的空调器测试标准参考国际标准ISO 16358:2013,但不同国家标准对于空调器能效的计算方式和温度分布略有不同,亚太市场高度相似。通过对亚太地区空调器能效标准的解读,总结归纳出亚太地区国家空调器能效测试标准的差异性、通用性和适用性,以利于空调器产品平台的开发,产品型号整合,提升产品开发效率,提高产品的通用化、标准化和差异化。
Abstract:
Mainly analyses the energy efficiency standards of air conditioners in the Asia-Pacific region. Finds that the energy efficiency standards of air conditioners in major countries of the Asia-Pacific region mainly refer to ISO 16358:2013, and the calculation method and temperature distribution for energy efficiency is different in various countries, but highly similar. Presents the energy efficiency standards in the Asia-Pacific region, and summarizes the differences, universality and applicability of energy efficiency test standards for the air conditioners, which is conducive to developing air conditioner product platforms, integrating product models, increasing product development efficiency and improving product universalization, standardization and differentiation.
Keywords:air conditioner, seasonal energy efficiency ratio, cooling capacity, test standard, Asia-Pacific region