暖通空调>期刊目次>2014年>第4期

快速启动式空气源热泵空调热水器性能实验

Experimental study on performance of quick starting air-source heat pump with domestic water heater

张欣然[1],董建锴[1],姜益强[1],沈德安[2]
[1]哈尔滨工业大学,[2]中铁第一勘察设计院集团有限公司

摘要:

针对现有空气源热泵热水器启动慢的问题,提出了快速启动式系统,并搭建了实验台。分析了现有系统启动慢的原因,介绍了快速启动式系统的原理及测试系统。测试数据表明,该快速启动式系统可以把启动时间缩短至4 min,系统制热水加制冷综合COP平均可达7.2。

关键词:空气源热泵,热水器,生活热水,快速启动,性能系数,实验

Abstract:

In order to solve the problem of slow starting of air-source heat pump water heater, puts forward the quick starting system and develops the test bed. Analyses the cause of slow starting, and presents the principle of quick starting system and testing system. Measured data show that the launching time can be shortened to 4 min, and overall COP can be improved to 7.2.

Keywords:air-source heat pump, water heater, domestic hot water, quick starting, COP, experiment
本站下载
镜像服务器下载