太阳辐射逐时化方法及软件实现
Method and software development of hourly solar radiation
摘要:
气象参数是建筑能耗模拟的基础,而逐时太阳辐射是建筑能耗模拟中最为重要的气象参数之一。介绍并比较了国内外逐时太阳总辐射模型和直散分离模型,选择C-P&R模型和Gompertz模型,采用MATLAB编程实现了全年太阳辐射的逐时化,并开发了相应的界面。利用开发的软件得到了上海气象台站2013年的逐时太阳总辐射、逐时直射数据和逐时散射数据,并和实际值作了比较。结果表明,计算得到的逐时太阳辐射数据符合全年辐射的变化规律,界面化的实现为建筑能耗模拟提供了便利。
Abstract:
Meteorologic parameter is the basis for building energy simulation and the hourly solar radiation is one of the most important meteorological parameters in building energy consumption simulation. Presents and compares the hourly total, direct and diffuse solar radiation models at home and abroad. Choosing C-P&R model and Gompertz model as tools, uses MATLAB to achieve full-year hourly solar radiation and develops the corresponding interface. Utilizing developed software obtains the hourly total, direct and diffuse solar radiations in Shanghai climate station in 2013 and compares them with the actual values. The results show that the calculated hourly solar radiation data accord with the annual variation radiation and the implementation of interface provides the convenience for building energy consumption.
Keywords:building energy consumption simulation, hourly total solar radiation, hourly direct and diffuse radiation, user interface, MATLAB