华东地区土壤及土沙混合物导热系数的实验研究
Experimental study on thermal conductivity of soil and its mixture with sand
摘要:
在不同含水率、不同密度条件下,利用探针法对土壤及不同比例的土沙混合物的导热系数作了实验研究,分析了影响土壤换热能力的因素,得到了便于工程使用的土壤及土沙混合物导热系数的实验关联式。
关键词:土壤,土沙混合物,导热系数,实验研究
Abstract:
Experimentally studies the thermal conductivity of soil and different ratio mixtures of sand and soil under different water ratio and density conditions by the thermo probe method. Analyses the factors affecting heat transfer performance of soil. Deduces four experimental correlations for thermal conductivity of soil and mixture of soil and sand, which are easy for project use.
Keywords:soil, mixture of soil and sand, thermal conductivity, experimental study