暖通空调>期刊目次>2008年>第2期

太阳能-土壤复合式地源热泵供暖的实验研究

Heating experiment of solar-ground-source hybrid heat pumps

王侃宏[1],李永[1],侯立泉[1],王宏伟[2],
[1]河北工程大学,[2]河北科技师范学院

摘要:

在所建立的太阳能-土壤复合式地源热泵实验台上,进行了单眼埋管井取热土壤源热泵供暖(模拟埋管面积不够的情形)和复合式地源热泵供暖的实验研究。结果表明,热泵机组从单眼埋管井取热时,冷凝器出水温度只有35 ℃左右,并且机组运行一段时间后,蒸发器出现结冰现象,造成了压缩机连续启停的不稳定工况;复合式系统运行时,蒸发压力始终保持在较高的水平,冷凝器出水温度达到43 ℃左右,可以满足风机盘管冬季工况的要求,复合式系统的机组平均制热性能系数为3.7。

关键词:太阳能-土壤复合式地源热泵,供暖,单眼埋管井,蒸发器,冷凝器

Abstract:

Conducts the heating experiment for ground-source heat pump with single underground exchanger well (simulating the situation of insufficient heat exchange area) and solar-ground-source hybrid heat pump on the established experiment table. The results show that when the ground-source heat pump with single underground exchanger well is in operation, the outlet water temperature of the condenser is only about 35 ℃ and the evaporator will freeze some time later resulting in frequent start-stop of the compressor, and that when the hybrid heat pump is in operation, the evaporator pressure keeps at a high level and the outlet water temperature of the condenser reaches about 43 ℃, sufficient to meet the heating demand of fan coil units in winter, and the average heating coefficient of performance of the hybrid heat pump is 3.7.

Keywords:solar-ground-sourcehybridheatpump,heating,singleundergroundexchangerwell,evaporator,condenser

    你还没注册?或者没有登录?这篇期刊要求至少是本站的注册会员才能阅读!

    如果你还没注册,请赶紧点此注册吧!

    如果你已经注册但还没登录,请赶紧点此登录吧!