摘要:
通过实验研究与理论分析相结合的方法,比较了连续运行模式、等时间间隔运行模式和非等时间间隔运行模式的供热量及室温调节效果,得出了最佳的供热运行模式,给出了对应不同建筑物耗热量指标的集热面积与供暖面积的比例。利用8个典型城市的气象数据,应用层次分析法计算得到了WSAC模块的气候适应性综合评价系数。
关键词:太阳能空气集热建筑模块,供暖能力,气候适应性,层次分析法
Abstract:
Based on experimental and theoretical analyses, investigates the heating supply and adjusting effects of room temperature in the three modes of fan running continuously, fan running in the equal time interval and fan running in the time interval varying with solar radiation, and obtains the optimal mode. Gives the ratios of collection area to heating area for buildings with different index of heat loss. Selecting meteorological data of eight typical cities, calculates the synthetic evaluation coefficient of climate adaptability by means of analytic hierarchy process.
Keywords:wall-mounted solar air collector,heating ability,climate adaptability,analytic hierarchy process