采用周线积分法计算人体与辐射板的辐射角系数
Radiation angle factor calculation between human body and radiant panel by contour integral method
摘要:
辐射角系数是计算人体与辐射板间辐射换热量的一个重要参数,针对人体与辐射板之间辐射角系数问题求解的复杂性,使用长方体模型代替站立姿态时的人体形状,进行辐射角系数的计算。以辐射顶板为例,运用周线积分法和代数法建立了任意位置下人体与辐射板之间辐射角系数的数学表达式,并对结论的合理性进行了验证。
关键词:辐射角系数,辐射板,周线积分法,长方体模型,有效辐射面积
Abstract:
Radiation angle factor is an important parameter for calculating the radiation heat transfer between human body and radiant panel. In view of the complexity of radiation angle factors between human body and radiant panel, considers the shape of a standing human body as a cuboid to calculate radiation angle factors. Takes the radiant ceiling for example, establishes basic mathematical expressions of radiation angle factor between human body and radiant panel by using contour integral method and algebraic method, and verifies the reasonability of the results.
Keywords:radiation angle factor, radiant panel, contour integral method, cuboid model, effective radiation area