高校学生宿舍夏季热舒适研究
Thermal comfort analysis of university dormitories in summer
摘要:
以西安某高校学生宿舍为研究对象,现场测试了宿舍内的温度和相对湿度等参数。通过问卷调查了学生对室内热环境的主观热感觉。研究结果表明,学生宿舍内的热环境处于ASHRAE给定的舒适区之外,80%以上的学生对室内热环境表示不满;但调查结果显示学生对室内热环境有一定的适应性。
关键词:高校宿舍 热环境 热舒适 热适应性
Abstract:
Tests the indoor temperature and relative humidity in the university dormitories in Xi’an. Surveys the subjective assessment of students on the indoor thermal environment by questionnaires. The results show that the thermal environment of the dormitories is out of the ASHRAE comfort zone and the proportion of the dissatisfaction of students on indoor thermal environment is up to 80%. On the other hand the results reveal that most of the students can acclimatize themselves well to the indoor thermal environment.
Keywords:university dormitory, thermal environment, thermal comfort, thermal adaptability