新型建筑构造铝电解厂房内隔墙局部阻力系数的实验研究
Experiment on coefficient of local resistance for perforated interior walls in a newstyle aluminum potroom
摘要:
对新型建筑构造铝电解厂房的内隔墙进行了实验,得到了不同开孔率的内隔墙、不同倾角的单层百叶以及固定隔栅的局部阻力系数值。结果表明内隔墙的局部阻力系数与其所用的材料和开孔率关系很大,而与通过气流的风速关系很小。
关键词:自然通风 铝电解厂房 局部阻力系数 实验
Abstract:
Makes an experiment on the perforated interior wall in a newstyle potroom, and works out the coefficient of local resistance for different perforated interior walls, single louvers and stationary grates. The results indicate that the materials and open pore ratio have obvious effects on the coefficient, and the air velocity has little effect.
Keywords:natural ventilation, aluminum potroom, coefficient of local resistance, experiment