广州西塔超高层玻璃幕墙选型的节能评价
Energy efficiency evaluation for glass curtain walls of Guangzhou West Tower super high-rise building
摘要:
以《公共建筑节能设计标准》为设计依据,根据西塔建筑特点对广州地区典型气象年数据中的室外气温和风速进行了修正。应用DeST软件,结合修正后的气象数据,分析了广州西塔传统单层玻璃幕墙和内呼吸双层通风幕墙的节能设计方案,根据能耗模拟结果对幕墙设计方案的静态投资回收期进行了估算。
关键词:公共建筑 节能评价 玻璃幕墙 典型气象年 回收期
Abstract:
According to the Design standard for energy efficiency of public buildings, revises the typical meteorological year data of Guangzhou based on the building characteristic of West Tower. Analyses the energy efficiency design of the conventional single skin and the active airflow double skin curtain wall by using the DeST software and the revised weather data. Evaluates the static payback period of curtain wall investment based on simulation results.
Keywords:publicbuilding,energyefficiencyevaluation,glasscurtainwall,typicalmeteorologicalyear,paybackperiod