严寒地区农村住宅保温窗帘的试验分析
Experimental analysis of insulation curtain for rural residential buildings in severely cold zone
摘要:
严寒地区农村住宅南向窗户较大,节能型农村住宅的窗户传热系数仍为墙体传热系数的5倍左右。在试验台上对保温窗帘和保温窗板的热工性能进行了测试。结果表明,采用保温窗帘(板)时,窗户的综合传热系数可降低13.5%~38%,从而使门窗传热能耗比例明显降低。
关键词:严寒地区,农村住宅,保温窗帘,保温窗板,节能,传热系数,热阻
Abstract:
The rural residential buildings in severely cold zones adopt larger windows, and the heat transfer coefficient of window is about four times more than that of wall for energy saving rural residential buildings. Tests the thermal performances of the insulation curtain and shutter. The results show that the overall heat transfer coefficient of the window reduced by 13.5% to 38% by adopting the curtain/shutter and the energy consumption fraction of door and window is markedly lowered.
Keywords:severely cold zone, rural residential building, insulation curtain, insulation shutter, energy saving, heat transfer coefficient, thermal resistance