摘要:

针对夏热冬冷地区的气候特征,分别从室内温度场、湿度场、风速场以及地板换热等出发,比较了住宅用冷却地板单独供冷、风机盘管单独供冷及两者联合运行三种供冷方式。结果显示,冷却地板与风机盘管联合运行可以满足夏季供冷要求,而且克服了冷却地板易结露的缺陷,具有良好的舒适性和节能性。

关键词:地板辐射供冷 风机盘管 结露 舒适性

Abstract:

For the climatic characteristics in hot summer and cold winter areas, from the aspects of indoor temperature field, humidity field, airflow velocity field and heat exchange from the floor, compares the three different cooling modes of floor panel cooling, fan coil cooling and the mode combining floor panel cooling with fan coil cooling. The results show that the combined mode  can meet cooling requirement in summer and eliminate condensation on the floor, therefore it is good in comfort and energy efficiency.

Keywords:floor panel cooling, fan coil, condensation, comfort