暖通空调>期刊目次>2009年>第1期

武汉长江隧道通风排烟问题的数值模拟研究

Numerical simulation for ventilation and smoke extraction system in Wuhan Yangtse Tunnel

方正[1],袁建平[1],齐运才[2],张雷[3]
[1]武汉大学,[2]机科发展科技股份有限公司,[3]中南建筑设计院

摘要:

采用大涡模拟火灾分析软件(FDS)分析不同火灾功率时通风速度对隧道烟气流动及温度分布的影响,可为今后的日常管理提供相关的运行控制参数。研究表明,在20 MW的火灾规模条件下,隧道通风速度以控制在2.5 m/s为宜。

关键词:隧道,通风,排烟,FDS,模拟

Abstract:

By the fire analysis software (fire dynamic simulator) of large eddy simulation (FDS), studies the impact of ventilation velocity on smoke flow and temperature distribution under different fire power magnitudes, which is expected to provide related operation control parameters for daily management. The research reveals that the ventilation velocity of 2.5 metres per second is desirable when the fire power is around 20 MW in magnitude.

Keywords:tunnel, ventilation, smoke extraction, FDS, simulation