太阳能百叶窗应用于主被动结合式太阳房的透光方式研究
Light transmission modes of solar blinds applied to active and passive combined solar houses
摘要:
在太阳能丰富的鄂尔多斯地区,针对主被动结合式太阳房南外窗耦合太阳能百叶窗展开了供暖实验研究,对比分析了太阳能百叶窗在室内透光面积最大和室内透光面积重合2种透光方式下室内温度分布规律。结果显示,太阳能百叶窗的透光方式对室内竖直温度场的影响差异较小,室内透光面积最大时夜间室内温度较高且在12~16 ℃范围内波动。建议采用透光面积最大的透光方式,能提高室内得热量。
Abstract:
In the solar energy-rich Ordos area, an experimental study on heating is carried out on the active and passive combined solar houses with the south exterior windows with solar blinds. The indoor temperature distribution is compared and analysed under two light transmission modes of making the maximum indoor light transmission area and overlapped indoor light transmission area. The results show that the light transmission mode of solar blinds has little influence on the indoor vertical temperature field, and the maximum indoor light transmission area corresponds to the higher indoor temperature at night which fluctuates in the range of 12 to 16 ℃. The light transmission mode with the maximum light transmission area is recommended, which can improve the indoor heat gain.
Keywords:solar blind; solar house; light transmission mode; light transmission area; temperature distribution; solar irradiance