Welcome to hvacjournal.cn      |  简体中文
  • About Journal
  • News
  • On-line Reading
  • Sample Copy
  • Advertisement
  • Subscribe e-Newsletter
  • Contact Us
  • Global Events
  • 2004
  • 2003n
  • 2005
  • 2006
  • 2007
  • 2008
  • 2009
  • 2010
  • 2011
  • 2012
  • 2013
  • 2014
  • 2015
  • 2016n
  • 2016n1
  • 2016n2
  • 2016n3
  • 2016n4
  • 2016n5
  • 2016n6
  • 2016n7
  • 2016n8
  • 2016n9
  • 2016n10

  • Exploration of vehicle-building-grid (VBG) collaborative interaction under dual carbon target

    Zhang Tao, Liu Xiaohua, Liu Xiaoc
  • Comparison of human thermal comfort improvement strategies in cold environments

    Fan Yuchen1,2, Cao Bin1,2
  • French high quality environment assessment system and application research

    Liu Maolin1,2, Meng Chong1,2, Zeng Luyao2, Hu An2,Wang Xiaofei2, Deng Yuechao2, Dai Ruiye3
  • Construction of information collection index system for air conditioning system based on energy management

    Ding Yong1,2,3, Yan Xue1,2,3
  • Interior and exterior zoning method of air conditioning system in office buildings based on dynamic load characteristic analysis

    Wei Zheng1, Qian Cheng2, Song Yehui1, Zhang Kun2, Qi Zewei1
  • Discussion on ventilation design for underground parking links

    Sun Libiao
  • Study on technical indicators of nearly zero energy residential buildings in Shanghai

    Qu Yan1,2, Song Dexuan1
  • Capacity configuration optimization of thermal storage air-conditioning systems based on annual hourly dynamic simulation

    Li Jintang1,2, Sun Zongyu1,2, Du Sicun3, Kong Weizheng4, Li Ji1,2,Feng Xiaomei1,2, Jiao Yuting5, Zhu Chao6
  • Discussion on implementation difference of GB 51251-2017 in various regions

    Fang Tianyu, Ma Hongmin, Hou Hongzhang
  • Optimization design analysis on air conditioning system of a large constant temperature aircraft assembly finishing plant

    Zou Licheng, Tao Chuan, Fu Jianxun, Shen
  • Analysis of large proportion heat recovery architecture in data centers

    Teng Shixing, Cai Weining, Yan Yongshuai
  • Method of initial flow distribution for ring truck line of heating network with goal of minimum initial investment

    Wang Yixin1,2, Wang Peng1,2, Zhang Shengting1,2, Wang Wei
  • Beijing Chao-Yang Hospital headquarter cooling load analysis and its application

    Hong Yang
  • Research on automatic optimization control strategy for variable-speed water-cooled direct cooling air conditioning units

    Chen Peisheng, Li Yang, Zhao Han
  • CFD simulation on thermal environment in subway station tunnels

    Zhang Yue, Li Xiaofeng
  • Study on stratified thermal flow in a displacement naturally ventilated room with two interacting point heat sources at the same height

    Yang Changqing1, Liu Yubo1, Li Angui1, Gao Xiaopan1,Gao Teng1, Luo Wenhao1, Qiao Lingmin2
  • Combined effects of indoor temperature, humidity and particulate concentration on PAEs concentration distribution in dustfall

    Sun Chanjuan1, Wang Ping1, Huang Xin1, Huang Chen1, Hong Shijie2
  • Study on adaptability of subway source heat pump systems

    Tong Li, Xia Yue, Ji Yongming, Wu Wenze, Hu Songtao
  • Optimization calculation method for cold source configuration of central air conditioning systems under different load characteristics

    Weng Dafu1, Wang Jianfei2
  • Experimental and simulation study on infection rate of SARS-CoV-2 under natural ventilation in classrooms of a university in Beijing

    Chen Hongbing1, Wang Wenqian1, Wang Congcong1, Zheng Tingting1 , Li Men1, Chen Liang2
  • Research on optimal ratio of solar-ground source heat pump system in severe cold and semi-arid region of Northwest China

    Zhang Hongge1,2, Li Yongfu3, Jin Guang4, Hao Nan2,5, Fang Lishuo6, Zhang Huijun7
  • Measurement analysis on operation effect and energy saving of adjustable water jet pumps for heating

    Liu Song1, Zhang Sisi1, Chen Lei1, Ao Xin1, Zhang Shengnan1, Yu Baofa2
  • Study on hydraulic balance regulation method of heating networks

    Zheng Lihong1,2, Zhou Zhihua1, Guo Xinchuan3, Wang Chendong1,2, Zhang Yunfei1
  • Research on water pump and terminal control methods of centralized heating systems using variable-flow air-source heat pumps

    Wu Chunsheng1,2,3, Wei Wenzhe4, Li Tianpu5, Ni Long2,3
  • Investigation and analysis of current indoor thermal environment in northern urban residences with centralized heating

    Liu Chang, Chen Chao, Lin Jie, Xie Jingchao, Ni Yu, Yin Peng, Yan Le
  • Some common problems and solutions in atmospheric pressure hot water boiler heating systems

    Wen Jintao1,2, Chen Yajuan1, Li Liujun1, Du Hongbo1
  • Stress analysis of new tee reinforced structure for directly buried heating pipelines

    Wang Yunyi1, Lei Yonggang1, Qian Heng1, Wang Fei1, Liang Li2
  • Home
  • About Journal
  • On-line Reading
  • Information
  • Advertisement
  • Contact Us

Copyright © hvacjournal.cn All Rights Reserved.