Welcome to hvacjournal.cn      |  简体中文
  • About Journal
  • News
  • On-line Reading
  • Sample Copy
  • Advertisement
  • Subscribe e-Newsletter
  • Contact Us
  • Global Events
  • 2004
  • 2003n
  • 2005
  • 2006
  • 2007
  • 2008
  • 2009
  • 2010
  • 2011
  • 2012
  • 2013
  • 2014
  • 2015
  • 2016n
  • 2016n1
  • 2016n2
  • 2016n3
  • 2016n4
  • 2016n5
  • 2016n6
  • 2016n7
  • 2016n8
  • 2016n9
  • 2016n10

  • Case study of residential air conditioning temperature setting behavior in Beijing

    Li Zhaojian
  • Application of static hydraulic balancing valves and self-operated differential pressure control valves to heating system

    Li Baoju, Yang Hong, Hao Hongtao and Li Xiaopeng
  • Influence of selection methods of external surface heat transfer coefficient on building load forecasting

    Yang Liu, Zhang Chen, Liu Yan, Liu Jiang, Hou Liqiang and Liu Jiaping
  • Effects of GSHP system on thermal environment of vegetation growth in Olympic Forest Park

    Liu Qiming and Zhang Zhiyao
  • Comparison and analysis of thermal insulation materials and thickness of heating pipeline in utility tunnel

    Wang Zhenhua, Wang Fei and Lei Yonggang
  • Application of personalized thermal comfort equipment to naturally ventilated classrooms

    Wang Xue, Yang Liu, Zhai Yongchao, Xu Cheng, Xu Qinyun, Shi Mingyang and Gao Siru
  • Cooling water waste heat recovery and utilization of refrigerating machines in cigarette factory

    Zhang Mengsheng and Ma Shuhe
  • Application of a novel air distribution mode to ventilation and air conditioning system of underground railway stations

    Liu Zhuomei
  • Principle and verification of a similar experiment system for vertical ground heat exchangers

    Peng Yuanling, Li Wenxin, Wei Kejuan, Xie Ye and Wang Yong
  • Performances of LiBr absorption-type heat pumps

    Kuang Shengyan, Zhou Junhua, Xie Jiping and Huang Weikai
  • Energy saving analysis on multi split household radiant air conditioning systems

    Chen Jianbo, Zhao Meng and Wang Fei
  • Leakage detection method of buried heating pipelines based on soil temperature and humidity

    Wu Jinxiang, Wang Yanxiao, Zhao Tao, Han Weiming and Wang Xiangwei
  • Risk assessment of facilities and equipment in high level biosafety laboratories based on fault tree analysis

    Cao Guoqing, Wang Rong and Zhou Yongyun
  • Comparative study on parameter systems of building envelope thermal storage performance

    Zhao Jinling and Dang Weikang
  • Energy consumption analysis of underground railway environmental control based on cluster analysis method

    Zhu Peigen, Ding Ru, Chen Qi and Wei Weizhi
  • Simulation of natural ventilation design for closed-boiler room of coal-fired power plants in hot summer and warm winter zone

    Huang Ting, Sun Wenlong and Li Qiong
  • Comfort evaluation of cabin environment in commercial aircrafts

    Liu Junjie, Jia Susu and Kang Jian
  • Time genetic period of heat consumption in heat supply station based on data regression

    Qi Chengying, Geng Xinxin, Sun Chunhua and Zhai Cancan
  • Optimization method for district energy station site selection and pipeline network using cluster analysis and minimum spanning tree

    Yu Zhen, Li Huai, Yuan Tao, Cheng Wenhui, Zhang Rongbing and Dong Fuhai
  • Experimental study of heat and moisture coupled transfer in single layer envelope

    Liu Qian, Kong Fanhong, Guo Xiaoqiang, Xie Ying and Chen Xiaoxiao
  • Inlet parameter optimization of double circuit cooling coil

    Chen Qinglong, Zhang Xiaobin, Zhang Xuejun, Zhao Yang and Zheng Youming
  • Thermal performance simulation and experimental study of elliptical tube finned evaporator

    Zheng Lintao, Zhao Lihua and Li Feng
  • Fault diagnosis of centrifugal chillers based on particle swarm optimization-least squares support vector machine

    Qing Hong, Han Hua, Cui Xiaoyu and Fan Yuqiang
  • Home
  • About Journal
  • On-line Reading
  • Information
  • Advertisement
  • Contact Us

Copyright © hvacjournal.cn All Rights Reserved.