Research on multi-person model of air conditioning usage behavior in office space
Wu Zejun, Pan Yiqun, Pan Yuan, Xie Jiantong and Huang Zhizhong
In a multi-person office, the air conditioning usage behavior is affected by the interaction among different people, and there is no suitable model to describe it accurately. Puts forward a method to build a model of multi-person air conditioning usage behavior: using intuitionistic fuzzy preference relationship to describe individual behavior preference and willingness, using subjective evaluation method to build a hierarchical structure to reflect the people’s social relationship, and combining with group decision-making method to describe the multi-person negotiation process, so as to build a multi-person model. The simulation results of air conditioning operation have a high similarity with the measured results, which can fully reflect the dynamic characteristics of the actual air conditioning operation state, indicating that the multi-person model is effective and reliable for the simulation of air conditioning usage behavior.