Human thermal adaptation in real building environment (2) —Comparison between centralized heating and individual heating in residential buildings

Cao Bin, Li Min, Ouyang Qin and Zhu Yingxin

2014.12.11

Conducts a field study in ten residences in Beijing for a whole winter. Among the residences, five are centralized heating (CH) users, and the other five use wall-mounted gas boiler, which is a typical kind of individual heating (IH). Measures indoor environmental parameters, and investigates thermal comfort situation of residents. The results show that the mean indoor temperature of IH residences is stable, and lower than that of CH residences. The neutral temperatures of IH users and CH users are 18.6 ℃ and 22.0 ℃ respectively. Compared with CH users, both thermal sensation and acceptability of indoor environment of IH users are higher at the same indoor temperature. Discusses the influence mechanism of individual control on thermal adaptation and heating of residences in hot summer and cold winter area.