On-site measured performance of radiant slab floor and fan-coil unit heating systems for residences in Yangtze River basin

Tang Haida, Zhang Tao and Liu Xiaohua

2017.11.23

In view of the selection of heating terminal types for residences in Yangtze River basin, concentrates on the on-site performance of the radiant slab floor and fan-coil unit heating systems combined with an air-source heat pump in two same residences in Hefei. The test results show that the radiant slab floor heating system provides a comfortable thermal environment with uniform temperature distribution in vertical direction and small temperature fluctuation. As hot air accumulates close to the ceiling, the indoor vertical temperature difference is relatively large for the fan-coil unit system with a bad air distribution. Keeping the same indoor operative temperature under continuous operation condition, the heat load of the radiant slab floor system is similar to that of the fan-coil unit system, whereas the EER of radiant slab floor system is 14% higher than that of the fan-coil unit system. Under intermittent operation condition,the dynamic response time of the radiant slab floor heating is longer than that of the fan-coil unit system which has quick start performance and provides higher comfort.