Temperature and humidity control measures for modern Panax Notoginseng planting greenhouses
Li Junkun, Liu Xiao and Wang Shun
Based on the climatic environment of temperate zone and the growth characteristics of Panax Notoginseng, designs the combined temperature and humidity control measures by calculation, analysis and simulation of whole professional BIM modeling. The combined temperature and humidity control measures mainly rely on sunshade cooling and natural ventilation, supplemented by mechanical ventilation and sprinkler cooling and humidification. The shade cooling measures automatically change the light transmission ratio of roof shade to reduce the solar radiation, the temperature detection system interlocks natural ventilation by windows and mechanical ventilation by root fan, and the humidity detection system interlocks automatic sprinkler humidification.