Energy saving effect of external thermal insulation of residential building under actual energy usage condition in hot summer and cold winter zone
Qian Xiaoqian, Ruan Fang, Qian Kuangliang and Wang Cong
According to Design standard for energy efficiency of residential buildings in hot summer and cold winter zone (JGJ 134-2010), there is a great difference between continuous energy utilization and actual energy usage. Based on the large scale of questionnaire survey in Hangzhou, a typical city in hot summer and cold winter zone, obtains the basic air conditioning behavior of local residents, the tolerant temperature and the average set temperature. Analyses the energy saving effects of the exterior thermal insulation of the residential buildings under different energy usage modes using building energy consumption simulation software DeST. The results show that reasonably setting the design condition in energy saving design standards is an important premise for accurately evaluating the energy saving effect of the exterior thermal insulation.