Measurement principle and application analysis of household radiator heat distribution method
Fang Xiumu, Li Hui, Li Qingyu, Jiang Yongcheng and Zhou Xinpeng
2014.12.18
Originated in Europe, the radiator heat distribution meter puts each radiator as calculated unit for heat distribution, but the heating system in our country is very difficult to satisfy the installation conditions of the radiator heat distribution meter. Converting a group of radiators of indoor horizontal one-pipe system into a set of equivalent heat sink can greatly reduce the number of radiator heat distribution meters and the installation requirements. Analyses the measurement principle of the household radiator heat distribution method, verifies the reasonability of its heat distribution model through experiment and gives the applicable scope of this method.