Application of dynamic airflow on split air conditioning unit and its impacts on human thermal comfort: isothermal condition

Luo Maohui, Yu Juan, Yang Yueting, Ouyang Qin and Zhu Yingxin

2014.12.18

Develops the dynamic air supply device of split air conditioning to produce simulated natural wind(SNW), and the spectrum analysis results are very close to natural wind in occupied zone. Performs the climate chamber experiments to reveal the occupants’ demand for air movement in different temperature environment and to compare the impacts of constant mechanical wind(CMW) and SNW on human thermal response. The results indicate that it is possible for subjects to remain thermal comfort in warm conditions of 28 ℃ and 30 ℃ with airflows, and the corresponding most suitable air velocity range is 0.4~0.6 m/s and 0.7~0.9 m/s, respectively. Compared with CMW, SNW can provide stronger cooling effect and better thermal comfort performance, which contributed to the consequence that over 60% subjects preferred SNW.