Characteristics of regenerative household ice storage air conditioning systems
Wu Weidong, Tang Hengbo, Chen Jie, Zhang Hua and Meng Jianjun
Considering the irregular work schedule of household air conditioning system, according to the theory of regeneration, develops a regenerative household ice storage air conditioning system. Analyses the influence of factors including ice thickness, initial evaporation temperature and hold-over coil diameter on the cold storage process. Tests the performances of the developed air conditioning system on conditions of cold storage mode and refrigeration-cold storage mode, respectively, and compares the test results with those of traditional air conditioning systems. The results show that the regenerator contributes to the solution to anti-frosting and anti-freezing of outside suction tube. The corresponding suction temperature of compressor is increased approximately by 25 ℃, and the evaporating temperature is increased approximately by 3 ℃ by applying regenerator. The resultant COP is improved by 3.6%. The system with refrigeration-cold storage mode solves the problem of unfixed service time for household air conditioning, which plays an important role in peak load shifting strategy.