Survey and inspired thoughts of air conditioning energy consumption in residential buildings
Li Zhaojian and Jiang Yi
Investigates the cooling energy consumption of five residential buildings with different air conditioning modes in Beijing in summer of 2006. Analyses the energy consumption characteristics of them and obtains the following results: 1) For the residential buildings with split air conditioners, air conditioners are installed more but operating time shorter, average energy consumption level is lower and the difference of cooling energy consumption among households is quite large;2) For three high-rise residential buildings in a high-class residential quarters, the rate of cooling energy consumption indexes among the buildings with split air conditioning, household air conditioning and central air conditioning is 1∶1.8∶6.7; 3) The energy consumption of air conditioning will rise to a large extent if household air conditioning or central air conditioning is applied to the residential buildings, and considers that the most suitable air conditioning mode for residential buildings in China is still that of choosing split air conditioners.