Human thermal comfort research in hot-humid area of China (2): comparison between research findings
Zhang Yufeng, Chen Huimei, Wang Jinyong and Meng Qinglin
Based on the climate chamber experiment results of human thermal comfort in hot-humid area of China, systematically compares and analyses the research results at home and abroad from the aspects of psychological thermal response, physiological thermal response and the relationship between psychology and physiology, and finds that the current international standard is not completely applicable to the hot-humid area of China mainly due to physiological thermal acclimatization and psychological thermal adaptation. The key approach to understand the basic thermal comfort response and set up the reasonable local thermal environment standard is to establish the thermoregulation model and psychological-physiological model considering the effects of thermal acclimatization and adaptation.