Decentralized heating for residential buildings in Yangtze River basin: A reforming case and analysis
Zhao Kang, Wu Mingyang, Tong Zhen, Liu Xiaohua, Jiang Yi
In view of the low indoor temperature and unsatisfactory thermal comfort in the residential buildings in Yangtze River basin, a heating system composed of air-source heat pump and radiant floor is installed in an existing residence in Hefei. The test results show that when hot water with temperature of 35℃ is adopted, the radiant floor heating could provide a comfortable thermal environment with indoor air temperature of 16 to 18℃ and uniform in the vertical direction. On the basis of this case, compares the air-supply terminal and radiant floor in indoor thermal comfort and heating capacity, and analyses the feasibility of air-source heat pump as heat source of decentralized heating for residential buildings in Yangtze River basin.