Key performance indicators for urban energy efficiency
Long Weiding, Fan Rui, Liang Hao and Liu Kuixing
Based on the characteristics of urban energy consumption in China, proposes that the urban energy consumption be divided into two types—productive energy consumption and consumptive energy consumption. The productive energy consumption can be evaluated by efficiency indicators; and the consumptive energy consumption should be evaluated as much as possible by physical quantity indicators, i.e. by the intensity indicator EUI (energy use intensity). The evaluating indicators should be measurable, verifiable and reportable. Relative indexes (such as the percentage indicators) must have a clear baseline. Presents the key performance indicators of urban productive and consumptive energy consumption, as well as of urban energy systems.