Reconstruction method of topology structure of multi-heat source ring-shaped heat-supply network under fault conditions
Wang Xiaoxia, Zhao Lihua and Zou Pinghua
Aiming at simulation problems for multi-heat source ring-shaped heat-supply network under fault conditions, presents the reconstruction method of topology structure of spatial heat-supply network, which is based on the graph theory, first searches the valves needed to be shut for insulation fault repair and only shuts the valves on the water supply pipe or return pipe of fault repair to utilize adequately standby function of ring-shaped heat-supply network, then affords the pipe segment and heat users to stop supply and puts up topology reconstruction under fault conditions. Develops a computer program, and the analysis on an example indicates that the method can commendably solve the simulation problem of dissymmetrical heat-supply network under fault conditions, which arithmetic is suitable for various types of heat-supply network with rapid convergence rate and high simulation precision.