Mode and method to carrying out community energy planning
Huang Zishuo, Yu Hang and Peng Zhenwei
Presents the significance and form of community energy planning (CEP) integrated with detailed planning of urban area. Points out the working emphasis of CEP in three levels, i.e. community, land block and building, under the mode. Emphasizes the optimization method of exergy flow allocation network among land blocks, i.e. two-stage planning method consisting of linear programming and goal programming. Provides the quantitative basis for the planning control indexes and planning scheme of each land block after selecting energy transform technology and optimizing the energy flow network, which is fundamental for incorporating the results of community energy planning into detailed urban planning documents.