Influence research of summer heatstroke prevention behavior modes on building energy consumption
Meng Zhihao Liu Dalong Feng Bencheng
To study the influence law of summer heatstroke prevention behavior modes on the building energy consumption,the representative cities in the hot summer and cold winter zone and hot summer and warm winter zone are selected.Taking a residential building as an example,under the condition of keeping the thermal performance of the building envelope unchanged,the DeST software is used to simulate.By comparing the difference of the influence of summer cooling behavior on the air conditioning energy consumption in these two thermal zones,the influence of summer heatstroke prevention behavior modes on the air conditioning energy consumption is studied,and the application mode of behavior modes in the dynamic energy consumption simulation method is explored.The results show that the heatstroke prevention behavior is significantly different under different climate types.The heatstroke prevention behavior has a significant impact on the building energy consumption.Compared with the simulation without the human behavior module,the cooling load per unit area with the human behavior module is reduced by 34.8 W/m2in the hot summer and cold winter zone,and 37.2 W/m2in the hot summer and warm winter zone,both showing obvious climatic differences.