Typical thermal and electrical load characteristics of residential buildings in Xizang Plateau villages and towns during winter

Lin Zhize1, Wang Dengjia1,2, Liu Yanfeng1,2, Wang Baichao1,Chen Yaowen1,2, Fu Zhiguo3, Men Duanyi1

2024.11.24

In view of the lack of correlational analysis of thermal and electrical loads based on energy-use behavior differences in current characterization of village and town residential loads, taking the residential buildings in Xizang Plateau villages and towns as the research object, through interviews and surveys, the information such as typical building structural characteristics and personnel activities is identified and summarized, and eight typical energy-use scenarios are extracted. The EnergyPlus simulation is employed to simulate and calculate the hourly thermal and electrical loads of typical residential buildings throughout the year under different energy-use behaviors. By utilizing the k-means clustering analysis, the thermal and electrical load characteristics of village and town residential buildings are extracted, and a method for dynamic load typification based on hourly load coefficients is proposed. Finally, through the parametric analysis of characteristic parameters, the energy-use characteristics of various types of users in Xizang Plateau village and town buildings under energy-use behavior differences are obtained.