Application and risk control of high temperature tissue degradation equipment in high-level biosafety laboratories

Tan Haibo1, Shi Fengxia2, Guo Fei1, Zou Guohua1, Cao Zhigang1

2024.11.24

In this paper, the application of high temperature tissue degradation equipment in high-level biosafety laboratories is analysed, and the principle and technical performance of this equipment are mainly presented. Based on the data of 121 batches (total of about 203 t) of animal residue innocuous treatment process, the performance and characteristics of high temperature tissue degradation equipment in practical using process are summarized. The key risk points of the high temperature tissue degradation equipment in the actual operation and maintenance process are identified and the specific control measures are given.