Correlation between indoor environment and heart rate of theelderly in Dalian elderly care buildings during heating season

Liu Weihua, Lü Yang, Lü Cheng, Zhu Rui, Wang Zhimeng, Ma Tengfei, Ye Xiaodong

2024.11.24

In order to understand the correlation between the indoor environment of elderly care buildings and the heart rate of the elderly, this study conducts a survey and household measurement on 26 households in urban and rural areas of Dalian during the heating season. The indoor environmental parameters and heart rate health are continuously monitored for 72 hours, and a questionnaire survey is used to obtain the subjective evaluation of the indoor environment of the elderly tested. The research results show that the indoor thermal environment of the surveyed urban residences is well, the indoor temperature of the urban residences is higher than that of the rural residences, and the fluctuations of temperature and humidity are less than those of the rural residences. Both rural and urban measured rooms have higher CO2concentrations, and the PM2.5 pollution in rural rooms is serious, 302% higher than the average concentration in urban rooms. There is no serious noise pollution in the measured rooms, the noise value exceeds the standard in some time periods, and the elderly in urban residences have higher requirements for the construction of an acoustic environment. The dynamic heart rate of the elderly is positively correlated with temperature, PM2.5 concentration and noise.